Product Name
LIFR, ELISA Kit
Full Product Name
Monkey LIFR (Leukemia Inhibitory Factor Receptor) ELISA Kit
Product Gene Name
LIFR elisa kit
[Similar Products]
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Sample Manual Insert
Download Sample PDF Manual View Sample PDF Manual
Request for Current Manual Insert
Request Current Manual
3D Structure
ModBase 3D Structure for P42702
Species Reactivity
Monkey
Specificity
This kit recognizes natural and recombinant Monkey LIFR. No significant cross-reactivity or interference between Monkey LIFR and analogues was observed.
Samples
Serum, Plasma, Biological Fluids
Detection Range
0.313-20ng/mL
Sensitivity
Min: 0.188ng/mL; Max: 20ng/mL
Preparation and Storage
Store at 4 degree C.
ISO Certification
Manufactured in an ISO 9001:2015 Certified Laboratory.
Product Note
Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of LIFR elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for LIFR purchase
MBS2509081 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the LIFR, ELISA Kit target analytes in
biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing LIFR. The ELISA analytical biochemical technique of the MBS2509081 kit is based on LIFR antibody-LIFR antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect LIFR antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, LIFR. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
Related Product Information for
LIFR elisa kit
Intended Uses: This ELISA kit applies to the in vitro quantitative determination of Monkey LIFR concentrations in serum, plasma and other biological fluids.
Principle of the Assay: This ELISA kit uses Sandwich-ELISA as the method. The micro ELISA plate provided in this kit has been pre-coated with an antibody specific to LIFR. Standards or samples are added to the appropriate micro ELISA plate wells and combined with the specific antibody. Then a biotinylated detection antibody specific for LIFR and Avidin-Horseradish Peroxidase (HRP) conjugate is added to each micro plate well successively and incubated. Free components are washed away. The substrate solution is added to each well. Only those wells that contain LIFR, biotinylated detection antibody and Avidin-HRP conjugate will appear blue in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color turns yellow. The optical density (OD) is measured spectrophotometrically at a wavelength of 450 nm +/- 2 nm. The OD value is proportional to the concentration of LIFR. You can calculate the concentration of LIFR in the samples by comparing the OD of the samples to the standard curve.
NCBI/Uniprot data below describe general gene information for LIFR. It may not necessarily be applicable to this product.
NCBI Accession #
NP_001121143.1
[Other Products]
NCBI GenBank Nucleotide #
NM_001127671.1
[Other Products]
UniProt Primary Accession #
P42702
[Other Products]
UniProt Secondary Accession #
Q6LCD9[Other Products]
UniProt Related Accession #
P42702[Other Products]
NCBI Official Full Name
leukemia inhibitory factor receptor
NCBI Official Synonym Full Names
leukemia inhibitory factor receptor alpha
NCBI Official Symbol
LIFR??[Similar Products]
NCBI Official Synonym Symbols
SWS; SJS2; STWS; CD118; LIF-R
??[Similar Products]
NCBI Protein Information
leukemia inhibitory factor receptor; CD118 antigen; LIF receptor
UniProt Protein Name
Leukemia inhibitory factor receptor
UniProt Synonym Protein Names
CD_antigen: CD118
Protein Family
Leukemia inhibitory factor receptor
UniProt Gene Name
LIFR??[Similar Products]
UniProt Synonym Gene Names
LIF receptor; LIF-R??[Similar Products]
UniProt Entry Name
LIFR_HUMAN
NCBI Summary for LIFR
This gene encodes a protein that belongs to the type I cytokine receptor family. This protein combines with a high-affinity converter subunit, gp130, to form a receptor complex that mediates the action of the leukemia inhibitory factor, a polyfunctional cytokine that is involved in cellular differentiation, proliferation and survival in the ***** and the embryo. Mutations in this gene cause Schwartz-Jampel syndrome type 2, a disease belonging to the group of the bent-bone dysplasias. A translocation that involves the promoter of this gene, t(5;8)(p13;q12) with the pleiomorphic adenoma gene 1, is associated with salivary gland pleiomorphic adenoma, a common type of benign epithelial tumor of the salivary gland. Multiple splice variants encoding the same protein have been found for this gene. [provided by RefSeq, Jul 2008]
UniProt Comments for LIFR
LIFR: Signal-transducing molecule. May have a common pathway with IL6ST. The soluble form inhibits the biological activity of LIF by blocking its binding to receptors on target cells. Defects in LIFR are the cause of Stueve-Wiedemann syndrome (SWS); also knowns as Schwartz-Jampel syndrome type 2 (SJS2). SWS is a severe autosomal recessive condition and belongs to the group of the bent-bone dysplasias. SWS is characterized by bowing of the lower limbs, with internal cortical thickening, wide metaphyses with abnormal trabecular pattern, and camptodactyly. Additional features include feeding and swallowing difficulties, as well as respiratory distress and hyperthermic episodes, which cause death in the first months of life. The rare survivors develop progressive scoliosis, spontaneous fractures, bowing of the lower limbs, with prominent joints and dysautonomia symptoms, including temperature instability, absent corneal and patellar reflexes, and smooth tongue. A chromosomal aberration involving LIFR is found in salivary gland pleiomorphic adenomas, the most common benign epithelial tumors of the salivary gland. Translocation t(5;8)(p13;q12) with PLAG1. Belongs to the type I cytokine receptor family. Type 2 subfamily. 2 isoforms of the human protein are produced by alternative splicing.
Protein type: Receptor, cytokine; Membrane protein, integral
Chromosomal Location of Human Ortholog: 5p13-p12
Cellular Component: integral to plasma membrane; receptor complex
Molecular Function: leukemia inhibitory factor receptor activity; oncostatin-M receptor activity; growth factor binding; ciliary neurotrophic factor receptor activity; ciliary neurotrophic factor receptor binding
Biological Process: cell surface receptor linked signal transduction; leukemia inhibitory factor signaling pathway; cytokine and chemokine mediated signaling pathway; response to cytokine stimulus; positive regulation of cell proliferation
Disease: Stuve-wiedemann Syndrome
Research Articles on LIFR
1. The LIFRalpha-CT3 TAT fusion protein can inhibit miR-155 expression
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.