Product Name
Coagulation Factor XIII B Polypeptide (F13B), ELISA Kit
Full Product Name
Bovine Coagulation Factor XIII B Polypeptide ELISA Kit
Product Gene Name
F13B elisa kit
[Similar Products]
Research Use Only
For Research Use Only. Not for use in diagnostic procedures.
Request for Current Manual Insert
Request Current Manual
Species Reactivity
Bovine
Samples
Serum, plasma, Cell Culture Supernatants, body fluid and tissue homogenate
Preparation and Storage
Store all reagents at 2-8 degree C.
Sample Preparation
We suggest pre-experimenting with neat (undiluted) samples, 1:2 or 1:4 dilutions. Please avoid diluting your samples more than 1:10 as it would exceed the dilution limit set for this kit. If the expected concentration of the target is beyond the detection range of the kit, please contact our technical support team
Product Note
Select online data sheet information is drawn from bioinformatics databases, occasionally resulting in ambiguous or non-relevant product information. It is the responsibility of the customer to review, verify, and evaluate the information to make sure it matches their requirements before purchasing the kit. Our ELISA Kit assays are dynamic research tools and sometimes they may be updated and improved. If the format of this assay is important to you then please request the current manual or contact our technical support team with a presales inquiry before placing an order. We will confirm the current details of the assay. We cannot guarantee the sample manual posted online is the most current manual.
Other Notes
Small volumes of F13B elisa kit vial(s) may occasionally become entrapped in the seal of the product vial during shipment and storage. If necessary, briefly centrifuge the vial on a tabletop centrifuge to dislodge any liquid in the container`s cap. Certain products may require to ship with dry ice and additional dry ice fee may apply.
Searchable Terms for F13B purchase
MBS747380 is a ready-to-use microwell, strip plate ELISA (enzyme-linked immunosorbent assay) Kit for analyzing the presence of the Coagulation Factor XIII B Polypeptide (F13B) ELISA Kit target analytes in
biological samples. The concentration gradients of the kit standards or positive controls render a theoretical kit detection range in biological research samples containing F13B. The ELISA analytical biochemical technique of the MBS747380 kit is based on F13B antibody-F13B antigen interactions (immunosorbency) and an HRP colorimetric detection system to detect F13B antigen targets in samples. The ELISA Kit is designed to detect native, not recombinant, F13B. Appropriate sample types may include undiluted body fluids and/or tissue homogenates, secretions. Quality control assays assessing reproducibility identified the intra-assay CV (%) and inter-assay CV(%).
NCBI/Uniprot data below describe general gene information for F13B. It may not necessarily be applicable to this product.
NCBI Accession #
NP_001985.2
[Other Products]
NCBI GenBank Nucleotide #
NM_001994.2
[Other Products]
UniProt Secondary Accession #
Q5VYL5; A8K3E5[Other Products]
UniProt Related Accession #
P05160[Other Products]
Molecular Weight
75,511 Da
NCBI Official Full Name
coagulation factor XIII B chain
NCBI Official Synonym Full Names
coagulation factor XIII, B polypeptide
NCBI Official Symbol
F13B??[Similar Products]
NCBI Official Synonym Symbols
FXIIIB
??[Similar Products]
NCBI Protein Information
coagulation factor XIII B chain; TGase; transglutaminase B chain; fibrin-stabilizing factor B subunit; protein-glutamine gamma-glutamyltransferase B chain
UniProt Protein Name
Coagulation factor XIII B chain
UniProt Synonym Protein Names
Fibrin-stabilizing factor B subunit; Protein-glutamine gamma-glutamyltransferase B chain; Transglutaminase B chain
Protein Family
Coagulation factor
UniProt Gene Name
F13B??[Similar Products]
UniProt Entry Name
F13B_HUMAN
NCBI Summary for F13B
This gene encodes coagulation factor XIII B subunit. Coagulation factor XIII is the last zymogen to become activated in the blood coagulation cascade. Plasma factor XIII is a heterotetramer composed of 2 A subunits and 2 B subunits. The A subunits have catalytic function, and the B subunits do not have enzymatic activity and may serve as a plasma carrier molecules. Platelet factor XIII is comprised only of 2 A subunits, which are identical to those of plasma origin. Upon activation by the cleavage of the activation peptide by thrombin and in the presence of calcium ion, the plasma factor XIII dissociates its B subunits and yields the same active enzyme, factor XIIIa, as platelet factor XIII. This enzyme acts as a transglutaminase to catalyze the formation of gamma-glutamyl-epsilon-lysine crosslinking between fibrin molecules, thus stabilizing the fibrin clot. Factor XIII deficiency is classified into two categories: type I deficiency, characterized by the lack of both the A and B subunits; and type II deficiency, characterized by the lack of the A subunit alone. These defects can result in a lifelong bleeding tendency, defective wound healing, and habitual abortion. [provided by RefSeq, Jul 2008]
UniProt Comments for F13B
F13B: The B chain of factor XIII is not catalytically active, but is thought to stabilize the A subunits and regulate the rate of transglutaminase formation by thrombin. Defects in F13B are the cause of factor XIII subunit B deficiency (FA13BD). FA13BD is an autosomal recessive disorder characterized by a life-long bleeding tendency, impaired wound healing and spontaneous abortion in affected women.
Protein type: Secreted; Secreted, signal peptide
Chromosomal Location of Human Ortholog: 1q31-q32.1
Cellular Component: extracellular region
Biological Process: blood coagulation
Disease: Factor Xiii, B Subunit, Deficiency Of
Research Articles on F13B
1. Data suggest that Factor XIII (composed of subunits F13A and F13B) increases rigidity/strength of fibrin clot, protects fibrin clot against shear stress in circulation, and protects fibrin from prompt elimination by fibrinolytic system. [REVIEW]
Precautions
All of MyBioSource's Products are for scientific laboratory research purposes and are not for diagnostic, therapeutics, prophylactic or in vivo use. Through your purchase, you expressly represent and warrant to MyBioSource that you will properly test and use any Products purchased from MyBioSource in accordance with industry standards. MyBioSource and its authorized distributors reserve the right to refuse to process any order where we reasonably believe that the intended use will fall outside of our acceptable guidelines.
Disclaimer
While every efforts were made to ensure the accuracy of the information provided in this datasheet, MyBioSource will not be liable for any omissions or errors contained herein. MyBioSource reserves the right to make changes to this datasheet at any time without prior notice.
It is the responsibility of the customer to report product performance issues to MyBioSource within 30 days of receipt of the product. Please visit our Terms & Conditions page for more information.